Simco-Ion’s Novx brand of Passive (Model 3352) and Active (Model 3362) Multi-fan Closed-loop Ionizer Controllers provide the capability to simultaneously detect, measure, record and monitor electrostatic voltages in multiple locations. The versatile antennas used with these systems allow their use in a variety of applications including monitoring sensitive workstations, in-tool voltages, or ionizer performance with the option of closed-loop control to select ionizer products. Up to 3 sensors can be connected to an individual instrument. This multi-channel capability provides a cost-effective monitoring solution for multiple areas or ionizers. Data input is actively monitored and logged with time stamps using Calibrator_Reader. The instruments have user settable thresholds and alarm levels that provide a proactive safeguard for critical areas when interfaced to an alarm output. Out of range conditions can trigger a remote alarm light or audible alarms, shut down a critical process, or make adjustments to an ionizing fan.
○ Digital, microprocessor-based controllers, multi-channel, digital I/O, auxiliary I/O, local addressability, RS-485/Modbus or Ethernet data output
○ Passive (unpowered) and active antenna configurations
○ Precision resolution
○ Programmable closed-loop control for up to 3 SSDC ionizer fans or a 3-fan blower
○ Programmable alarm set-points with tool shutdown option
○ Voltage/polarity displays, local red/green LEDs each channel
Model 3352 | Model 3362 | |
---|---|---|
Input Voltage | 24 VDC | 24 VDC |
Capacity | 1,2 or 3 fans | 1,2 or 3 fans |
Reporting Range | 0 to ±5000V | 0 to ±150V |
Accuracy | 1V for <20V; ±5% for >20V | 1V for <20V; ±5% for >20V |
Audible Alarm Set-points | ±0.5V (min) | ±1V (min) |
LEDs/Channel | Red/green or alarm indicator | Red/green or alarm indicator |
Alarm Set-point | Programmable | Programmable |
Zero Set-point | Programmable | Programmable |
Aux Out | Open collector | Open collector |
Output Signals | Digital | Digital |
Antennas | up to 3 channels | up to 3 channels |
Decay Testing | NA | up to 3 channels |
Communication | Novx Comm,RS-485/Modbus,Ethernet | Novx Comm,RS-485/Modbus,Ethernet |
Digital Display/Channel | 4-Digit | 4-Digit |
Dimensions | 5.1W x 17.3D x 16.5H cm | 5.1W x 17.3D x 16.5H cm |
Weight | 0.95 kg | 1 kg |
Enclosure | Stainless Steel | Stainless Steel |
Warranty | Two-year limited warranty | Two-year limited warranty |
Certifications |
![]() |
![]() |
Power Adapter 14-21327 | |
---|---|
Input Voltage | 100-240 VAC 50/60 Hz |
Output Voltage | 24 VDC,30W |
Dimensions | 10.3H x 4.2W x 2.9D cm |
Weight | 140g |
Certifications |
![]() |
• It can detect static voltage after located sensors into sensitive area .NOVX system could record data and Alarm, Novx could upload all data to PC when connected by cable. And loop-control ionizers